|
2008, Volume 14 No. 2
ARTICLE 3
Changes in Nutritional, Functional Status and Quality of Life of COPD Out-patients after a Pulmonary Rehabilitation Programme in HUKM: a Pilot Study
Suzana S1, Hanis MY1, Tang SY1, Ayiesah R2
& Roslina AM3
1 Department of Nutrition and Dietetics, Faculty of Allied Health Sciences, Universiti Kebangsaan
Malaysia, 50300, Kuala Lumpur, Malaysia
2 Department of Physiotherapy, Faculty of Allied Health Sciences, Universiti Kebangsaan Malaysia,
50300, Kuala Lumpur, Malaysia
3 Department of Medicine, Faculty of Medicine, Universiti Kebangsaan Malaysia, 56300 Cheras,
Kuala Lumpur, Malaysia
ABSTRACT
This study sought to examine the reliability of two measurements; Calf Circumference
(CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years
and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during
the period of December 2005 to January 2006, upon consent, were recruited to the
study. There was a high degree of reliability for both inter- and intra-examiner (r close
to 1). For inter-examiner, on average the CC measurements taken by the first examiner
were 0.3 cm lower than that of the second examiner. The upper and lower limit of the
differences were +0.4 to –0.9 cm respectively. Inter-examiner MHAS measurements
on average by the first examiner were 0.2 cm lower than that of the second examiner.
The limits were +1.7 to –2.1 cm. By comparison, the inter-examiner CC measurements
were more reliable than the MHAS measurements. For intra-examiner, on average the
CC measurements at Time 1 were consistent with Time 2 (mean difference=0) with
limits of the difference at + 0.5 cm. MHAS measurements at Time 1 were on average
0.1 cm less than at Time 2 with limits at +1.7 and –1.8 cm. The technical error of
measurement (TEM) and coefficient of variation of CC and MHAS for both interexaminer
and intra-examiner measurements were within acceptable limits with the
exception of MHAS TEM. This study suggests that CC and MHAS measured in elderly
persons 60 years and above, using Seca Circumference Tape® 206, Germany (0.05 cm)
are reliable and can be used in a community survey.
Full Article >>
|
|
 |
|
March 1995, Vol1 No.1
September 1995, Vol1 No.2
March 1996, Vol2 No.1
September 1996, Vol2 No.2
March 1997, Vol3 No.1
September 1997, Vol3 No.2
December 1998, Vol4 No.1&2
December 1999, Vol5 No.1&2
March 2000, Vol6 No.1
September 2000, Vol6 No.2
Mar/Sept 2001, Vol7 No.1&2
March 2002, Vol8, No.1
September 2002, Vol8, No.2
March 2003, Vol9 No.1
September 2003, Vol9 No.2
March 2004, Vol10 No.1
September 2004, Vol10 No. 2
2005, Vol 11 No.1
2005, Vo l11 No.2
2006, Vol 12 No.1
2006, Vol 12 No.2
2007, Vol 13 No.1
2007, Vol 13 No.2
March 2008, Vol 14 No.1
2008, Vol 14 No.2
2009, Vol 15 No.1
2009, Vol 15 No.2
2010, Vol 16(1)
2010, Vol 16(2)
2010, Vol 16(3)
2011, Vol 17(1)
2011, Vol 17(2)
2011, Vol 17(3)
|
|
|
|