 |
|
MALAYSIAN JOURNAL
OF |
|
NUTRITION |
Official publication of
the Nutrition
Society of Malaysia
Since March 1995
|
2008, Volume 14 No. 2
ARTICLE 2
Reliability and Technical Error of Calf Circumference and Mid-half Arm Span Measurements for Nutritional Status Assessment of Elderly Persons in Malaysia
Jamaiyah H1, Geeta A1, Safiza MN2, Wong NF2, Kee CC3, Ahmad AZ2, Suzana S4 , Rahmah R5 , Khor GL6 , Ruzita AT4, Chen WS1, Rajaah M1 & Faudzi A2
1 Clinical Research Centre, Hospital Kuala Lumpur, Malaysia
2 Institute for Public Health, Kuala Lumpur, Malaysia
3 Institute for Medical Research, Kuala Lumpur, Malaysia
4 Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
5 Hospital Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia
6 Universiti Putra Malaysia, Serdang, Selangor, Malaysia
ABSTRACT
This study sought to examine the reliability of two measurements; Calf Circumference
(CC) and Mid-half Arm Span (MHAS). A sample of 130 elderly persons aged 60 years
and above seen consecutively in the Kuala Lumpur Hospital outpatient clinic during
the period of December 2005 to January 2006, upon consent, were recruited to the
study. There was a high degree of reliability for both inter- and intra-examiner (r close
to 1). For inter-examiner, on average the CC measurements taken by the first examiner
were 0.3 cm lower than that of the second examiner. The upper and lower limit of the
differences were +0.4 to –0.9 cm respectively. Inter-examiner MHAS measurements
on average by the first examiner were 0.2 cm lower than that of the second examiner.
The limits were +1.7 to –2.1 cm. By comparison, the inter-examiner CC measurements
were more reliable than the MHAS measurements. For intra-examiner, on average the
CC measurements at Time 1 were consistent with Time 2 (mean difference=0) with
limits of the difference at + 0.5 cm. MHAS measurements at Time 1 were on average
0.1 cm less than at Time 2 with limits at +1.7 and –1.8 cm. The technical error of
measurement (TEM) and coefficient of variation of CC and MHAS for both interexaminer
and intra-examiner measurements were within acceptable limits with the
exception of MHAS TEM. This study suggests that CC and MHAS measured in elderly
persons 60 years and above, using Seca Circumference Tape ® 206, Germany (0.05 cm)
are reliable and can be used in a community survey.
Full Article >>
|
|
 |
|
March
1995, Vol1 No.1 |
|
September
1995, Vol1 No.2 |
|
March
1996, Vol2 No.1 |
|
September
1996, Vol2 No.2 |
|
March
1997, Vol3 No.1 |
|
September
1997, Vol3 No.2 |
|
December
1998, Vol4 No.1&2 |
|
December
1999, Vol5 No.1&2 |
|
March 2000, Vol6 No.1 |
|
September 2000,
Vol6 No.2 |
| Mar/Sept 2001,
Vol7 No.1&2 |
|
March 2002, Vol8, No.1 |
|
September 2002, Vol8, No.2 |
|
|
March 2003, Vol9 No.1 |
| |
| |
| |
| |
| |
| |
| |
|
| |
|
|
|
|
|
|
Please note that you need to have Acrobat
Reader 3.0 or 4.0 to download and view the articles. If you do not
have a copy, click onto the ADOBE logo here to get a copy of
the software

 |
|
MALAYSIAN JOURNAL OF NUTRITION |
|
Guidelines for submitting manuscripts.
more detail >> |
|
|
|
|